  • 产品信息全-2(1).png
  • 2(4).png

INFICON CDG100D

Classification:

Electrical

Product Name:

Pressure Measuring Instruments


Contact Online Inquiry
  • Description
  • Parameters

    CDG100D gauges are temperature controlled at 100°C and have superior performance in demanding semiconductor and plasma processes. They are available in full scales from 100MTERR to 1000TERR, with all common flange types and fieldbus interfaces, and provide a linear 0 to 10V, gas type independent, pressure signal. Resistive capacitance manometers use corrosion-resistant, ultra-pure aluminum oxide ceramic diaphragms.

  • ● Vantage 

    (1) Lower CoO (Cost of Ownership), 50% faster warm-up, energy efficient and low power consumption

    (2) Easy integration, wide variety of full scales, flanges, and interfaces, two setpoints standard

    (3) Simple one-button or remote signal zero command with adjustable zero offset

    (4) Diagnostic port for fast repair and maintenance

    (5) Two-year warranty for longer service life, advanced heating concept and instrument protection

    (6) No need for long-term recalibration due to excellent signal stability and repeatability, even in harsh plasma applications

    (7) Conformity and Standards: CE, EN, UL, SEMI, RoHS


    ● Typical Application

    (1) Etching, CVD, PVD and other semiconductor production processes

    (2) Chemical and corrosive high temperature processes

    (3) General thin film and vacuum processes requiring instrumentation protection

     

    ● Norm 

    1000 ... 500 Torr / mbar:

       

     Accuracy(1) % of reading% of reading 0.2
    Resolution percent FS 0.003
    Output signal(analog) V(dc) 0 ...+10
    Response time(2) ms 30
    Materials exposed to vacuum  

    Aluminum oxide ceramic((AI2O3),

    stainless steel(AISI 316L (4)

     

    200 ... 1 Torr / mbar :   

     

      
    Accuracy(1) % of reading 0.2
    Resolution percent FS 0.003
    Output signal(analog) V(dc) 0 ...+10
    Response time(2) ms 30
    Materials exposed to vacuum  

    Aluminum oxide ceramic((AI2O3),

    stainless steel(AISI 316L (4)

     
    0.5 ... 0.1 Torr / mbar:  
     
      
    Accuracy(1) % of reading 0.2
    Resolution percent FS 0.003
    Output signal(analog) V(dc) 0 ...+10
    Response time(2) ms 30
    Materials exposed to vacuum  

    Aluminum oxide ceramic((AI2O3),

    stainless steel(AISI 316L (4)

Preceding Page

Next Page

Related Products


Enquire Now

If you are interested in our products, please leave your e-mail, we will contact you as soon as possible, thank you!

Security verification